How to lower the costs of Anti-foam Agents in Potato Processing Facilities

How to Lower or Eliminate Anti-foam Chemical Costs in Potato Processing Facilities

As water flows through a food processing facility, air becomes increasingly entrained within its volume. Once air makes its way to the surface, foam begins to form and grow.

September 10, 2018

'How to lower Costs of Anti-foam Agent in potato processing facilities' is based on materials provided to PotatoPro by ChemFree Defoam LLC. The content of the original article has been edited for clarity and to fit the PotatoPro platform.


Until now, anti-foam chemicals (defoamers) were the only commercially viable solution for foam control. Accordingly, processing plants are designed with this solution in mind.

However, with the rising prices of these chemicals and with the growing concern about processing chemicals being added to our food, the food industry is re-thinking its approach to foam control and prevention.

While non-chemical solutions are now available for foam control, there are also inexpensive, but effective, improvements for existing facilities that address foam prevention. These improvements can fit into the routine maintenance of an existing plant and add little, or nothing, to the overall maintenance budget.

There are also proactive modifications in existing facilities that will prevent foam creation with a very short-term payoff.

For facilities that are currently in the design phase, there are numerous cost-effective design options that will greatly reduce, or eliminate, the need for anti-foam chemicals.

Improving Water Transport Systems

As water flows through a facility, air becomes increasingly entrained within its volume. Once air makes its way to the surface, foam begins to form and grow. The rate of foam growth increases with the amount of entrained air.

Thus, every effort should to made to minimize entraining air into the processing water.

Aside from the entrained air, two other physical parameters influence the rate of foam growth. These are the speed at which the water is moving and obstructions in the path of flowing water. The faster that water moves the less likely it is to have localized foaming issues. As moving water impinges upon surface obstruction, foam tends to gather and grow.

This article describes specific physical designs that contribute to foam growth due to one or more of the above-mentioned issues and the suggested modifications that minimize these issues.

Water Entering Tanks from Pipes


A typical condition that exists in a water transport system is where water leaves a pipe and enters a tank.

If emerging water strikes the surface of the water in the tank (left), more air becomes entrained, thus, more foam is generated.However, by immersing the end of the pipe so as to have the emerging water exit below the surface (right) the effect of an air/water interface is greatly minimized

If emerging water strikes the surface of the water in the tank (left), more air becomes entrained, thus, more foam is generated.However, by immersing the end of the pipe so as to have the emerging water exit below the surface (right) the effect of an air/water interface is greatly minimized

For such an event, should the emerging water strike the surface of the water in the tank (left), more air becomes entrained, thus, more foam is generated.

However, by immersing the end of the pipe so as to have the emerging water exit below the surface (right) the effect of an air/water interface is greatly minimized, reducing, or eliminating, the creation of additional foam.

This improvement can be attained by simply adding an extension to an existing pipe immersing it deep enough so as not to create unacceptable surface turbulence.

Water Entering Tanks from Flumes


Constraining the flow

Ideally, it would be advantageous to convert water emerging from a flume (a “waterfall” condition) so as to confine it to a closed pipe and treat it as mentioned before.

However, this can be a difficult task, due, in part, to foaming consequences of making any transition to water flow.

Water flow transitions, e.g., directional changes, flow speed changes, increasing confinement, etc., often result in unwanted turbulence and more foam. Thus, careful design considerations need to be taken into account should such an approach be implemented.

Utilizing turbulent flow

Another approach to controlling foam produced from the impact of processing water from a flume into a tank is to take advantage of its turbulent flow upon entering the water.

Turbulence, while a source for entraining air and subsequently producing foam, can also be used to an advantage in controlling foam.

Typically, no foam is produced in the immediate vicinity where the processing water strikes the surface of the tank water. Instead the turbulent flow carries the entrained air down into the water volume where it subsequently rises and emerges at the surface as foam. The distance from the impact area where this foam emerges is dependent upon the speed and direction of the processing water as it strikes the surface.

Foam that makes its way into the impact area is either destroyed or is carried back into the tank water.

Utilizing turbulent flow, it is possible to design systems whereby foam levels in tanks being fed by open flumes reach an equilibrium and are maintained at acceptable levels.

Utilizing turbulent flow, it is possible to design systems whereby foam levels in tanks being fed by open flumes reach an equilibrium and are maintained at acceptable levels.

Utilizing this turbulent flow description, it is possible to design systems whereby foam levels in tanks being fed by open flumes reach an equilibrium and are maintained at acceptable levels.

The figure above depicts such a configuration. Here the turbulent flow of the incoming process water has a horizontal velocity component moving it beneath the water toward the opposite end of the tank where it is diverted into the reverse direction.

This reverse flow completes a “closed loop” in which the surface foam is driven back into the impact area where it is either destroyed or is carried into the turbulent flow beneath the surface…repeating the cyclic process.

Water in Flumes and Open Floor Drains


Increase flow speed

It is more difficult for foam to grow in rapidly moving water compared to slowly moving or still water. The pitch of drains and flumes should be as high as reasonably dictated by the surroundings.

Physical obstructions

Regardless of the water flow speed, any level of surface foam being transported with the water will readily adhere to obstructions in the path of the flow. As the water continues to pass, the oncoming surface foam will attach itself to that already present, resulting in an area with continuous foam growth.

Ideally, obstructions should be removed. If that is not possible, a smooth streamlined diversion that allows the water to “slip” by the obstruction without adhering to it (shown above)

Ideally, obstructions should be removed. If that is not possible, a smooth streamlined diversion that allows the water to “slip” by the obstruction without adhering to it (shown above)

Two types of obstructions are common in food processing facilities:

  • “Hard” obstructions

    These refer to physical objects such as pipes, flume discontinuities, and surface irregularities. Once identified, the ideal solution is to simply remove these obstructions.

    Knowing this is not always reasonable, the second approach to solve the problem is to introduce a smooth streamlined diversion that allows the water to “slip” by the obstruction without adhering to it as illustrated above.

    Example of a proper design for a closed pipe

    Example of a proper design for a closed pipe

    A hard obstruction that is commonly observed is the flow of water from a pipe into a drain, often a floor drain. This input is often at or near 90o, meaning that the ingress stream strikes the wall of the drain straight on. This causes turbulence and more foam creation.

    Moreover, it creates a “soft” obstruction (see below) for the water flowing in the drain. Water introduced into a drain should always enter as parallel to the drain direction as possible, and in the same direction as the flowing drain water.

    Example of a proper design for an open trench (gutter)

    Example of a proper design for an open trench (gutter)

  • “Soft” obstructions

    • Foam: One type of soft obstruction is foam itself. Foam deposits become “seeds” for foam growth. Foam that comes in contact will easily adhere to it, especially if that foam is stationary.

      The solution is to prevent these “seeds” from forming…the means for which is the subject of this article.

    • Water: A second soft obstruction is water. When flowing water meets water from another source turbulence ensues - add air and foam is created.

      Depending upon the flow dynamics, the flow of either source can slow down which can also contribute to additional foam creation.

      To minimize this obstruction, the same design criteria as illustrated for a closed pipe or an open trench are recommended.

    • Debris: Another obstruction classified as “soft” is debris. Food processing debris often collects in flumes, especially in drains.

      This problem is usually alleviated by increasing the speed of the water flowing in the drain. Where possible the pitch is increased.

      Other means include the insertion of a high impact nozzle directing water (preferably re-cycled water) toward the debris in the direction of the water flow.

Drain Covers

Drain covers can help keep foam down. They can be used for localized foaming areas and to direct foam to other areas for subsequent treatment.

Several materials are available for this purpose including polyvinyl chloride, urethane, and silicone-based materials.

Anti-Foam Distribution System

It is common throughout the food processing industry to inject anti-foam chemicals into one location of a closed loop water transport system. This loop usually consists of several potential foaming areas, i.e., multiple tanks, flumes, wash tables, starch recovery areas, etc.

Quite often the amount of anti-foam injected into each loop is controlled at a central location where the anti-foam and pumps are located.

While such a distribution system seems to be operationally efficient, it overuses defoamers and therefore wastes money.

There are several reasons for this:

  • First, the anti-foam needs for each area on the loop will vary, which necessarily means that chemicals are being wasted - enough for one area is overkill for other areas.

  • Second, anti-foam is also wasted because the effectiveness of the chemicals diminishes as it moves away from the injection point.

    This is due to the dilution of the anti-foam chemicals by the large volume of water in the loop, the adherence of the anti-foam chemicals to product within the loop, and the performance degradation of anti-foam over time.
By judicious de-centralization of some of the anti-foam injection points defoaming effectiveness can be greatly enhanced:

“Put the medicine where the pain is.”

Conclusion

Making reasonable modifications of the physical plant of existing food processing facilities and/or by incorporating these modifications into the design for new facilities will significantly reduce the expenses associated with using anti-foam chemicals.

Moreover, by combining these modifications with the recently available non-chemical means for foam destruction, chemical costs will dwindle…possibly to zero.
Like to receive news like this by email? Join and Subscribe!
Join Our Telegram Channel for regular updates!
Sponsored Content

Highlighted Company

Sponsored Content
Sponsored Content
Sponsored Content
Sponsored Content
Sponsored Content

Where

Sponsored Content